resetcounters

Controls whether impstats resets counters after emitting them so they show deltas.

This parameter applies to impstats: Generate Periodic Statistics of Internal Counters.

Name:

resetcounters

Scope:

module

Type:

boolean

Default:

module=off

Required?:

no

Introduced:

at least 5.x, possibly earlier

Description

When set to on, counters are automatically reset after they are emitted. In that case, they contain only deltas to the last value emitted. When set to off, counters always accumulate their values. Note that in auto-reset mode not all counters can be reset. Some counters (like queue size) are directly obtained from internal objects and cannot be modified. Also, auto-resetting introduces some additional slight inaccuracies due to the multi-threaded nature of rsyslog and the fact that for performance reasons it cannot serialize access to counter variables. As an alternative to auto-reset mode, you can use rsyslog’s statistics manipulation scripts to create delta values from the regular statistic logs. This is the suggested method if deltas are not necessarily needed in real-time.

Module usage

module(load="impstats" resetCounters="on")

See also

See also impstats: Generate Periodic Statistics of Internal Counters.


Support: rsyslog Assistant | GitHub Discussions | GitHub Issues: rsyslog source project

Contributing: Source & docs: rsyslog source project