.. _param-omlibdbi-db: .. _omlibdbi.parameter.input.db: DB == .. index:: single: omlibdbi; DB single: DB .. summary-start Names the database schema that omlibdbi writes to. .. summary-end This parameter applies to :doc:`../../configuration/modules/omlibdbi`. :Name: DB :Scope: input :Type: word :Default: input=none :Required?: yes :Introduced: Not documented Description ----------- Set this to the database instance that should receive the syslog events. It must exist on the selected server and accept the credentials supplied via ``UID`` and ``PWD``. Input usage ----------- .. _param-omlibdbi-input-db-usage: .. _omlibdbi.parameter.input.db-usage: .. code-block:: rsyslog action(type="omlibdbi" driver="mysql" server="db.example.net" \ uid="dbwriter" pwd="sup3rSecret" db="syslog") Legacy names (for reference) ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Historic names/directives for compatibility. Do not use in new configs. .. _omlibdbi.parameter.legacy.actionlibdbidbname: - $ActionLibdbiDBName — maps to DB (status: legacy) .. index:: single: omlibdbi; $ActionLibdbiDBName single: $ActionLibdbiDBName See also -------- See also :doc:`../../configuration/modules/omlibdbi`.